| Type |
Gaz |
|---|
| Type |
Fireplaces |
|---|
| Collection | Ortal Traditional (Signature & Wilderness) |
|---|---|
| Brand | Ortal |
| Energy | Natural gas or propane |
| Models Included | Traditional 90, Traditional 110, Wilderness Traditional 36, Wilderness Traditional 42 |
| Viewing Area | 35-7/16″ × 31-5/8″ (Trad. 90 / Wild. 36); 42-11/16″ × 34-1/8″ (Trad. 110 / Wild. 42) |
| Interior Options | Black Reflective Glass, Blackridge, brick panels (red or tan). |
Ortal Traditional Collection brings the classic fireplace up to date with clean, adjustable, and safe gas combustion. Depending on the desired style, you can choose between the Wilderness burner (flames through the logs) for striking wood realism, and the Signature burner for a full, elegant flame. The Traditional 90/110 (Signature) and Wilderness Traditional 36/42 (Wilderness) models offer generous viewing areas, a 5″×8″ co-axial vent, and various interior media (brick, Blackridge, black glass) to integrate the fireplace into traditional or contemporary settings.
• Two flame styles: Wilderness (flame through the logs) or Signature (full, even flame).
• Power and efficiency: up to 55,000 BTU/h on Traditional 90/110 models (Signature) and ≈32,000 BTU/h on Wilderness Traditional 36/42, with AFUE up to ~81–84% depending on fuel.
• 5×8 Direct Vent (co-axial) and Power Vent option for long runs.
• Thermal barrier: micro-mesh screen (and double glass available on Wilderness 36/42).
• Comfort & control: remote control, Wi-Fi control, interior lighting, discreet fans.
Ortal Traditional fireplaces are direct vent appliances. Installation must be performed by a qualified contractor according to CSA B149.1 Code (natural gas/propane) and the clearances/finishes specified in the manuals and framing sheets. The Cool Wall/Heat Control option allows integration of a television or heat-sensitive finish above the fireplace, when implemented according to manufacturer’s instructions.
Anti-reflective glass and ceramic media require light maintenance; plan for an annual inspection of venting and seals, as well as seasonal cleaning of the screen/double-glass. Technical documents (cuts, templates, manuals) specify the framing and maintenance requirements specific to each model.
| Model | Burner | Viewing Area (W × H) | Max BTU (NG) | Max BTU (LPG) | Efficiency (AFUE) | Venting | Thermal Barrier | Interiors (examples) | Controls |
|---|---|---|---|---|---|---|---|---|---|
| Traditional 90 | Signature | 35-7/16″ × 31-5/8″ | 55 000 | 34 459 | NG 77.8% / LPG 81.4% | 5″×8″ co-axial Direct Vent | Micro-mesh screen | Black Reflective, Blackridge, Brick | Remote Control, Wall Switch |
| Traditional 110 | Signature | 42-11/16″ × 34-1/8″ | 55 000 | 34 459 | NG 77.8% / LPG 81.4% | 5″×8″ co-axial Direct Vent | Micro-mesh screen | Black Reflective, Blackridge, Brick | Remote Control, Wall Switch |
| Wilderness Traditional 36 | Wilderness | 35-7/16″ × 31-5/8″ | 32 163 | 31 400 | NG 79.7% / LPG 79.8% | 5″×8″ co-axial Direct Vent | Double glass or micro-mesh screen | Black Reflective, Blackridge, Brick | Remote Control, Wi-Fi, Wall Switch |
| Wilderness Traditional 42 | Wilderness | 42-11/16″ × 34-1/8″ | 32 163 | 31 400 | NG 79.7% / LPG 79.8% | 5″×8″ co-axial Direct Vent | Double glass or micro-mesh screen | Black Reflective, Blackridge, Brick | Remote Control, Wi-Fi, Wall Switch |
Conversion or new construction project in Greater Montréal? Visit our showroom to see the Traditional 90/110 and Wilderness 36/42 in operation. Our advisors will size the venting (5×8 or Power Vent), validate clearances, and provide you with a turnkey quote compliant with CSA B149.1.
Ortal Traditional Collection: classic gas fireplaces with modern innovations. Choose Wilderness (flames through the logs) or Signature. Models covered: Traditional 90/110 and Wilderness Traditional 36/42. Up to 55,000 BTU/h, 5×8 co-axial vent, micro-mesh screen/double glass options, brick/Blackridge/glass interior media. Professional installation compliant with CSA B149.1 recommended.
Oui, lorsque l’installation respecte le manuel et la gestion de chaleur Cool Touch Wall, qui permet de réduire la chaleur en façade pour abaisser le téléviseur plus près du foyer. Les schémas de montage TV et exigences de rejets/chaleur sont détaillés par Flare; toujours suivre le manuel d’installation et la configuration de heat-release recommandée.
Le ST-45 est un foyer à évent direct (système coaxial scellé). La fiche technique liste un raccord 4×6 en configuration naturelle, et 3×5 avec power vent. Le manuel couvre les parcours, terminaisons horizontales/verticales et les dégagements au conduit. Un installateur qualifié doit valider le tracé sur place.
La puissance d’entrée maximale est de 36 000 BTU/h en gaz naturel (GN) et 28 000 BTU/h en propane (PL). Le fabricant annonce une efficacité jusqu’à 82 % (GN) / 83 % (PL). Les performances réelles varient selon la configuration, le réglage et la qualité d’évacuation.
Flare indique une certification CSA pour l’installation en Amérique du Nord. La garantie prévoit 18 mois sur l’électronique, 5 ans sur les vitrages (bris thermique) et 10 ans limités sur la boîte foyère et les brûleurs. Au Québec, l’installation du gaz doit respecter le Code CSA B149.1 et le manuel du fabricant.